11.25 KIPS (50 KN) ADMET MODEL 2613 (EP2 SERVO CONTROL)
Tension Testing opening/Compression Testing Opening: 52”
Distances between columns/screws: 16.8”
Table Size: 16.8" * 5"
Electro-Mechanical Unispace Tension and Compression (S/N: 351210A) Testing Stroke: 46”
Testing Speed: .00002-20 IPM
Crosshead adjusting speed: 20 IPM Weight: 375 lbs
10K (50 kN) Interface Load Cell S/N: 351210A
Pressure suction as high as 14.4 kPa (300 psf) over the roof assembly is produced by a 74.4-kW (100 hp) fan with a flow rate of 5000 L/s (10594.4 ft3 /min)
Top Chamber, Bottom Frame with 12 by 24 ft in size that structurally strong with four lifting mechanisms for the top chamber to a maximum height of 10 ft from the ground. (Items #1 and #2)
Fan system (Blower and Inverter) that can simulate a minimum of 300 psf suction (Item #3)
Gust simulator (Flap and Servo Motor) that can reproduce the CSA A123.21 wind gusts (Item #4)
Sensors and Data acquisition system necessary to measure the system performance as per CSA A123.21 (Item #5)
Control system that runs the CSA A123.21 test protocol via executable software